Products


Stage & Lighting Cable 

 
Conductors: Bare Copper
Separator: Water resistant separator
Insulation: Thermoplastic Rubber
Construction: Bare copper conductor is rope stranded and covered with a water resistant safety separator, insulation is thermoplastic rubber.
Applications: Portable power cable for use in motion picture, television studios, theatre and similar locations with temperatures ranging from -30°C to 105°C.
Approvals: UL listed PPE/TPE 600 Volts, 105°C dry, 90°C outdoor, and 75°C immersed in water. Passes UL854 Flame Test. 
NEC Article 520 and 530 
cUL PPC 600 Volts, 90°C indoor and outdoor use. FT5 Oil resistant, Water resistant
 

Click on part number to add RFQ.

EISL UL PPE/TPE cUL PPC

Part Number
AWG
Size
Stranding
Nominal
Conductor
O.D.
Nominal
Cable
O.D.
Weight
Lbs/1000'
Ampacity*
J21A51-*8168.150.26013080
J21A54-*6266.202.412155105
J21A65-*4420.254.465205140
J21A57-*2665.326.538295190
J21A59-*1833.360.615390200
J21A61-*1/01064.410.660460260
J21A64-*2/01330.456.720585300
J21A67-*3/01672.510.770720350
J21A70-*4/02109.580.830870405

* Values given are for a single conductor in free air 30°C ambient temperature.


Print this page